{"id":4162,"date":"2022-08-18T16:13:00","date_gmt":"2022-08-18T13:13:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4162"},"modified":"2026-02-27T15:45:21","modified_gmt":"2026-02-27T13:45:21","slug":"16di-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/16di-v1-1\/","title":{"rendered":"IOMod 16DI V1.1"},"content":{"rendered":"\n<p><strong>IOMod 16DI <\/strong>is a stand-alone Modbus (RTU), IEC 60870-5-101 and IEC60870-5-103 digital input controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 16DI is used for industrial applications where digital signaling is used and robust communication is essential.<\/p>\n\n\n\n<p><strong>IOMod 16DI<\/strong> is an ideal solution for such applications as data acquisition, observation, control, process monitoring, testing, and remote measurement. It is controlled over Modbus, IEC 60870-5-101 or IEC60870-5-103 protocol, and can be connected in parallel with other Modbus, IEC 60870-5-101 or IEC60870-5-103 equipment in a multi-drop installation scheme as in any SCADA system.<\/p>\n\n\n\n<p>When using <strong>IOMod 16DI<\/strong> with <a href=\"\/wcc-lite\" data-type=\"URL\" data-id=\"\/wcc-lite\" target=\"_blank\" rel=\"noreferrer noopener\">WCC Lite gateway<\/a> it is possible to monitor\/control the I\/O signals over Ethernet LANs or 3G\/4G(LTE)\/GSM\/GPRS networks. It is a powerful solution for remote monitoring and control, alarm management, and data logging of I\/O\u2019s on CloudIndustries.eu cloud platform.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>16 digital inputs<\/li>\n\n\n\n<li>Configurable active input signal polarity or input inversion<\/li>\n\n\n\n<li>Configurable SPI, DPI<\/li>\n\n\n\n<li>Pulse count and ON time count<\/li>\n\n\n\n<li>Galvanically isolated inputs<\/li>\n\n\n\n<li>Configuration over USB console<\/li>\n\n\n\n<li>Drag and Drop firmware upgrade over USB mass storage<\/li>\n\n\n\n<li>Modbus, IEC 60870-5-101 or IEC60870-5-103 communication over RS485<\/li>\n\n\n\n<li>Software selectable termination resistor on RS485<\/li>\n\n\n\n<li>LED indication for input and data transmission<\/li>\n\n\n\n<li>Easy connection with WCC Lite gateway and CloudIndustries.eu platform<\/li>\n<\/ul>\n\n\n\n<p><strong>System<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PC USB connection: Mini USB<\/li>\n\n\n\n<li>Input connectors: Screw terminal plug connector<\/li>\n<\/ul>\n\n\n\n<p><strong>Software<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Configuration: Over USB console<\/li>\n\n\n\n<li>Firmware upgrade: Over USB mass storage<\/li>\n<\/ul>\n\n\n\n<p><strong>Communication<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Communication standard: RS485<\/li>\n\n\n\n<li>Communication protocol: Modbus RTU, IEC 60870-5-101 and IEC60870-5-103<\/li>\n\n\n\n<li>Speed: 600 \u2013 115200 baud<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-16DI<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">16 Digital input module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility, Serial console (putty)* <\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Inputs and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Digital inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">16<\/td><\/tr><tr><td>Input voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">12-24 VDC<\/td><\/tr><tr><td>Input signal polarity<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable<\/td><\/tr><tr><td>Input inversion<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable<\/td><\/tr><tr><td>Input filter<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable (0..256000ms)<\/td><\/tr><tr><td>Input counter <\/td><td class=\"has-text-align-left\" data-align=\"left\">16 (one per input) with a reset function<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-33VDC (full range)<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">40mA @ 12VDC, 20mA @ 24 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Relative humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 17.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*  IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x, for devices with fw v1.x configuration can be done via USB port as Serial console interface like Putty.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\" rel=\"noreferrer noopener\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-16di-iomod-16di-8\">IOMOD-16DI<\/a> &#8211;  16 Digital input module with IEC 60870-5-103, IEC 60870-5-101, or Modbus RTU Slave protocol<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">On request*:<\/h3>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">ON REQUEST AVAILABLE MODULES WITH INPUT VOLTAGES 48VDC.<\/mark> <\/p>\n\n\n\n<p>* &#8211; IOMOD devices 8DI8DO, 8AI, 4RTD, 16DI, 8DI4RO, HT with firmware versions v1.x supports only 1 protocol. To change protocol is required to change firmware. All types of firmware are accessible to all customers without any additional payment. <\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD 16DI inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>IOMod 16DI is a stand-alone Modbus (RTU), IEC 60870-5-101 and IEC60870-5-103 digital input controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 16DI is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 16DI is an ideal solution for such applications [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":1677,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4162","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IOMod 16DI V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IOMod 16DI V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"IOMod 16DI is a stand-alone Modbus (RTU), IEC 60870-5-101 and IEC60870-5-103 digital input controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 16DI is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 16DI is an ideal solution for such applications [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/16di-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-27T13:45:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/\",\"url\":\"https:\/\/elseta.com\/16di-v1-1\/\",\"name\":\"IOMod 16DI V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png\",\"datePublished\":\"2022-08-18T13:13:00+00:00\",\"dateModified\":\"2026-02-27T13:45:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/16di-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png\",\"width\":851,\"height\":566},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/16di-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IOMod 16DI V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IOMod 16DI V1.1 | elseta.com","robots":{"index":"noindex","follow":"follow"},"og_locale":"lt_LT","og_type":"article","og_title":"IOMod 16DI V1.1 | Elseta","og_description":"IOMod 16DI is a stand-alone Modbus (RTU), IEC 60870-5-101 and IEC60870-5-103 digital input controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 16DI is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 16DI is an ideal solution for such applications [&hellip;]","og_url":"https:\/\/elseta.com\/16di-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-02-27T13:45:21+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/16di-v1-1\/","url":"https:\/\/elseta.com\/16di-v1-1\/","name":"IOMod 16DI V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/16di-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/16di-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png","datePublished":"2022-08-18T13:13:00+00:00","dateModified":"2026-02-27T13:45:21+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/16di-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/16di-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/16di-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-16DIr.png","width":851,"height":566},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/16di-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"IOMod 16DI V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4162"}],"version-history":[{"count":2,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4162\/revisions"}],"predecessor-version":[{"id":4164,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4162\/revisions\/4164"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/1677"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4162"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4162"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}