{"id":4200,"date":"2022-08-25T12:22:00","date_gmt":"2022-08-25T09:22:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4200"},"modified":"2026-02-27T15:46:26","modified_gmt":"2026-02-27T13:46:26","slug":"8di8ro-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/8di4ro-v1-1\/","title":{"rendered":"8DI4RO V1.1"},"content":{"rendered":"\n<p><strong>IOMod 8DI4RO<\/strong> is a stand-alone Modbus-RTU, IEC 60870-5-101, and IEC 60870-5-103 digital input and relay output controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 8DI4RO is used for industrial applications where digital signaling is used and robust communication is essential.<\/p>\n\n\n\n<p><strong>IOMod 8DI4RO<\/strong> is an ideal solution for such applications as data acquisition, observation, control, process monitoring, testing, and remote measurement. It is controlled over Modbus, IEC 60870-5-101 or IEC 60870-5-103 protocol, and can be connected in parallel with other Modbus, IEC 60870-5-101 or IEC 60870-5-103 equipment in a multi-drop installation&nbsp;scheme as in any SCADA system.<\/p>\n\n\n\n<p>When using <strong>IOMod 8DI4RO<\/strong> with <a rel=\"noreferrer noopener\" href=\"\/wcc-lite\" target=\"_blank\">WCC Lite<\/a> it is possible to monitor\/control the I\/O signals over Ethernet LANs or 3G\/4G(LTE)\/GSM\/GPRS networks. It is a powerful solution for remote monitoring and control, alarm management, and data logging of I\/O\u2019s on CloudIndustries.eu cloud platform.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>8 digital inputs<\/li>\n\n\n\n<li>Configurable input inversion and digital debounce filter<\/li>\n\n\n\n<li>Configurable SPI, DPI, SCO, and DCO support<\/li>\n\n\n\n<li>Configurable feedback for outputs with inputs<\/li>\n\n\n\n<li>Configurable pulse outputs and permanent outputs<\/li>\n\n\n\n<li>Input grouping<\/li>\n\n\n\n<li>Output grouping<\/li>\n\n\n\n<li>Feedback configurable time<\/li>\n\n\n\n<li>4 relay outputs<\/li>\n\n\n\n<li>Galvanically isolated inputs and outputs<\/li>\n\n\n\n<li>Configuration over USB console<\/li>\n\n\n\n<li>Drag and Drop firmware upgrade over USB mass storage<\/li>\n\n\n\n<li>Modbus, IEC 60870-5-101 and IEC-60870-5-103 communication over RS485<\/li>\n\n\n\n<li>Software selectable termination resistor on RS485<\/li>\n\n\n\n<li>LED indication for input\/output and data transmission<\/li>\n<\/ul>\n\n\n\n<p><strong>System<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Digital inputs: 8<\/li>\n\n\n\n<li>Relay outputs: 4 (normal outputs contact)<\/li>\n\n\n\n<li>PC USB connection: Mini USB<\/li>\n\n\n\n<li>Input\/output connectors: Screw terminal plug connector<\/li>\n<\/ul>\n\n\n\n<p><strong>Software<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Configuration: Over USB and RS485<\/li>\n\n\n\n<li>Firmware upgrade: Over USB and RS485<\/li>\n<\/ul>\n\n\n\n<p><strong>Communication<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Communication standard: RS485<\/li>\n\n\n\n<li>Communication protocol: Modbus (RTU), IEC 60870-5-101, and IEC 60870-5-103<\/li>\n\n\n\n<li>Speed: 600 \u2013 115200 baud<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-8DI4RO V1.1<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">8 Digital inputs and 4 relay outputs module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility, Serial console (putty)* <\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Inputs and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Digital inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">8<\/td><\/tr><tr><td>Input voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">12-48 VDC<\/td><\/tr><tr><td>Input signal polarity<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable<\/td><\/tr><tr><td>Input inversion<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable<\/td><\/tr><tr><td>Input filter<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable (0..256000ms)<\/td><\/tr><tr><td>Input grouping<\/td><td class=\"has-text-align-left\" data-align=\"left\">Up to 4 groups of DPI<\/td><\/tr><tr><td>Relay outputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">4 (normally open contact)<\/td><\/tr><tr><td>Output current <\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;5A at 250VAC Resistive load<br>&lt;2A at 250VAC Inductive load (cos&nbsp;\u03c6&nbsp;= 0.4, L\/R = 7 ms)<br>&lt;5 A at 30 VDC Resistive load<br>&lt;2 A at 30 VDC Inductive load (cos&nbsp;\u03c6&nbsp;= 0.4, L\/R = 7 ms)<br>(per each output)<\/td><\/tr><tr><td>Output max switching voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">277 VAC, 125 VDC (max switching current 5A)<\/td><\/tr><tr><td>Output functions<\/td><td class=\"has-text-align-left\" data-align=\"left\">Permanent or Pulse output<\/td><\/tr><tr><td>Output pulse<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable in ms (0..60s)<\/td><\/tr><tr><td>Output feedback time<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configurable in ms (0..60s)<\/td><\/tr><tr><td>Output grouping<\/td><td class=\"has-text-align-left\" data-align=\"left\">up to 2 groups DCO<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>9-48VDC (full range)<\/strong><\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">120mA @ 12VDC, 60mA @ 24 VDC, 30mA @ 48 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Relative humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non-condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 22.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*  IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x, for devices with fw v1.x configuration can be done via USB port as Serial console interface like Putty.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-8di4ro-iomod-8di4ro-12583\" data-type=\"link\" data-id=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-8di4ro-iomod-8di4ro-12583\">IOMOD-8DI4RO<\/a> &#8211;  8 Digital inputs and 4 relay outputs module with IEC 60870-5-103, IEC 60870-5-101, Modbus RTU Slave protocols<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">On request*:<\/h3>\n\n\n\n<p class=\"has-white-color has-text-color\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-green-cyan-color\">ALL IOMOD-8DI4RO MODULES WITH INPUT VOLTAGES from 12VDC to <span style=\"text-decoration: underline;\">48VDC<\/span>.<\/mark><\/p>\n\n\n\n<p> * &#8211; IOMOD devices 8DI8DO, 8AI, 4RTD, 16DI, 8DI4RO, HT with firmware versions v1.x supports only 1 protocol. To change protocol is required to change the firmware. All types of firmware are accessible to all customers without any additional payment. For firmware, version v2.x is included all protocols and is configurable with IOMOD configuration tools.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD 8DI4RO inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>IOMod 8DI4RO is a stand-alone Modbus-RTU, IEC 60870-5-101, and IEC 60870-5-103 digital input and relay output controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 8DI4RO is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 8DI4RO is an ideal solution [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":1685,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4200","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>8DI4RO V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"8DI4RO V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"IOMod 8DI4RO is a stand-alone Modbus-RTU, IEC 60870-5-101, and IEC 60870-5-103 digital input and relay output controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 8DI4RO is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 8DI4RO is an ideal solution [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/8di4ro-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-27T13:46:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/\",\"url\":\"https:\/\/elseta.com\/8di4ro-v1-1\/\",\"name\":\"8DI4RO V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png\",\"datePublished\":\"2022-08-25T09:22:00+00:00\",\"dateModified\":\"2026-02-27T13:46:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/8di4ro-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png\",\"width\":851,\"height\":566},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/8di4ro-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"8DI4RO V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"8DI4RO V1.1 | elseta.com","robots":{"index":"noindex","follow":"follow"},"og_locale":"lt_LT","og_type":"article","og_title":"8DI4RO V1.1 | Elseta","og_description":"IOMod 8DI4RO is a stand-alone Modbus-RTU, IEC 60870-5-101, and IEC 60870-5-103 digital input and relay output controller. Designed to achieve a high technological look and compact fit on DIN rail (EN 60715), IOMod 8DI4RO is used for industrial applications where digital signaling is used and robust communication is essential. IOMod 8DI4RO is an ideal solution [&hellip;]","og_url":"https:\/\/elseta.com\/8di4ro-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-02-27T13:46:26+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/8di4ro-v1-1\/","url":"https:\/\/elseta.com\/8di4ro-v1-1\/","name":"8DI4RO V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png","datePublished":"2022-08-25T09:22:00+00:00","dateModified":"2026-02-27T13:46:26+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/8di4ro-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/8di4ro-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/8di4ro-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8DI4RO-v1-r.png","width":851,"height":566},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/8di4ro-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"8DI4RO V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4200"}],"version-history":[{"count":3,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4200\/revisions"}],"predecessor-version":[{"id":4204,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4200\/revisions\/4204"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/1685"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4200"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4200"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}