{"id":4269,"date":"2022-09-15T15:51:00","date_gmt":"2022-09-15T12:51:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4269"},"modified":"2025-09-15T15:54:43","modified_gmt":"2025-09-15T12:54:43","slug":"iomod-8ai-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/product\/iomod-8ai-v1-1\/","title":{"rendered":"IOMod 8AI V1.1"},"content":{"rendered":"\n<p><strong>IOMod 8AI <\/strong>is a stand-alone Modbus RTU, IEC60870-5-103 and IEC60870-5-101 8 analog input device. Designed to measure voltage or current values with high accuracy in real-time. IOMod 8AI can be used for numerous applications where user needs to log Voltage or Current changes. IOMod 8AI can be used to measure temperature, pressure, water level or weight with corresponding sensors (e.g. 4-20mA). IOMod 8AI input measurement resolution, data scaling and data casting can be configured by user for each channel individually.<\/p>\n\n\n\n<p><strong>IOMod 8AI<\/strong> is an ideal solution for such applications as data acquisition, observation, control, process monitoring, testing and measurement remotely. It is controlled over Modbus, IEC60870-5-101 or IEC 60870-5-103 protocol, and can be connected in parallel with other Modbus, IEC60870-5-101 or IEC 60870-5-103 equipment in a multi-drop installation scheme such as any SCADA system.<\/p>\n\n\n\n<p>When using <strong>IOMod 8AI<\/strong> with WCC Lite gateway, it is possible to monitor voltage or current values for each individual input over Ethernet LAN\u2019s or 3G\/4G(LTE)\/GSM\/GPRS networks. It is a powerful solution for remote monitoring and control, alarm management and data logging of I\/Os on CloudIndustries.eu cloud platform.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Data measurement in 16-bit resolution<\/li>\n\n\n\n<li>Fully configurable data scaling and casting<\/li>\n\n\n\n<li>Selectable input sensitivity<\/li>\n\n\n\n<li>Configuration over USB console<\/li>\n\n\n\n<li>Drag and Drop firmware upgrade over USB mass storage<\/li>\n\n\n\n<li>Modbus RTU, IEC 60870-5-101 and IEC-60870-5-103 communication over RS485<\/li>\n\n\n\n<li>Software selectable 120\u03a9&nbsp;termination resistor for RS485<\/li>\n\n\n\n<li>LED indication for data transmission<\/li>\n\n\n\n<li>Easy connection with WCC Lite gateway and CloudIndustries.eu platform<\/li>\n<\/ul>\n\n\n\n<p><strong>System<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analog inputs: 8<\/li>\n\n\n\n<li>PC USB connection: Mini USB<\/li>\n\n\n\n<li>Input connectors:&nbsp;Screw terminal plug connector<\/li>\n<\/ul>\n\n\n\n<p><strong>Software<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Configuration: Over USB console<\/li>\n\n\n\n<li>Firmware upgrade: Over USB mass storage<\/li>\n<\/ul>\n\n\n\n<p><strong>Communication<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Communication standard: RS485<\/li>\n\n\n\n<li>Communication protocol: Modbus (RTU), IEC 60870-5-101, and IEC 60870-5-103<\/li>\n\n\n\n<li>Speed: 600 \u2013 115200 baud<\/li>\n<\/ul>\n\n\n\n<p><strong>Electrical characteristics<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Termination resistor:&nbsp;Software selectable, 120\u03a9<\/li>\n\n\n\n<li>Power supply: 9-33VDC (full range)<\/li>\n\n\n\n<li>Current consumption: 40mA @ 12VDC, 20mA @ 24VDC<\/li>\n\n\n\n<li>Inputs:&nbsp;16-bit resolution<\/li>\n\n\n\n<li>Channel-independent programmable inputs<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-8AI<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">8 channel 16 bit analog input module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility, Serial console (putty)* <\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Measurement values and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Analog inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">8 configurable analog inputs<\/td><\/tr><tr><td>Inputs resolution<\/td><td class=\"has-text-align-left\" data-align=\"left\">16 bit<\/td><\/tr><tr><td>Channel-independent programmable input types<\/td><td class=\"has-text-align-left\" data-align=\"left\">Voltage and current inputs<\/td><\/tr><tr><td>Voltage input ranges<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bipolar: +-10.24V, +-5.12V, +-2.56V<br>Unipolar: 10.24V, 5.12V<\/td><\/tr><tr><td>Current input ranges<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bipolar: +-51.2mA, +-25.6mA, +-12.8mA<br>Unipolar: 51.2mA, 25.6mA<\/td><\/tr><tr><td>Overvoltage protection<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;+-20V<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.0<\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-33VDC (full range)<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">40mA @ 12VDC, 20mA @ 24 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Relative humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 17.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*  IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x, for devices with fw v1.x configuration can be done via USB port as Serial console interface like Putty.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\" rel=\"noreferrer noopener\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-8ai-iomod-8ai-27\">IOMOD-8AI<\/a> &#8211;  8x analog input module with IEC 60870-5-103, IEC 60870-5-101, or Modbus RTU Slave protocol<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">On request*:<\/h3>\n\n\n\n<p> * &#8211; IOMOD devices 8DI8DO, 8AI, 4RTD, 16DI, 8DI4RO, HT with firmware versions v1.x supports only 1 protocol. To change protocol is required to change firmware. All types of firmware are accessible to all customers without any additional payment. <\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD 8AI inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>IOMod 8AI is a stand-alone Modbus RTU, IEC60870-5-103 and IEC60870-5-101 8 analog input device. Designed to measure voltage or current values with high accuracy in real-time. IOMod 8AI can be used for numerous applications where user needs to log Voltage or Current changes. IOMod 8AI can be used to measure temperature, pressure, water level or [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":1670,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4269","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IOMod 8AI V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IOMod 8AI V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"IOMod 8AI is a stand-alone Modbus RTU, IEC60870-5-103 and IEC60870-5-101 8 analog input device. Designed to measure voltage or current values with high accuracy in real-time. IOMod 8AI can be used for numerous applications where user needs to log Voltage or Current changes. IOMod 8AI can be used to measure temperature, pressure, water level or [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-15T12:54:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/\",\"url\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/\",\"name\":\"IOMod 8AI V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png\",\"datePublished\":\"2022-09-15T12:51:00+00:00\",\"dateModified\":\"2025-09-15T12:54:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png\",\"width\":851,\"height\":566},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produktai\",\"item\":\"https:\/\/elseta.com\/lt\/produktai\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IOMod 8AI V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IOMod 8AI V1.1 | elseta.com","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/","og_locale":"lt_LT","og_type":"article","og_title":"IOMod 8AI V1.1 | Elseta","og_description":"IOMod 8AI is a stand-alone Modbus RTU, IEC60870-5-103 and IEC60870-5-101 8 analog input device. Designed to measure voltage or current values with high accuracy in real-time. IOMod 8AI can be used for numerous applications where user needs to log Voltage or Current changes. IOMod 8AI can be used to measure temperature, pressure, water level or [&hellip;]","og_url":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2025-09-15T12:54:43+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/","url":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/","name":"IOMod 8AI V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png","datePublished":"2022-09-15T12:51:00+00:00","dateModified":"2025-09-15T12:54:43+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-8AIr.png","width":851,"height":566},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/lt\/product\/iomod-8ai-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Produktai","item":"https:\/\/elseta.com\/lt\/produktai\/"},{"@type":"ListItem","position":3,"name":"IOMod 8AI V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4269"}],"version-history":[{"count":2,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4269\/revisions"}],"predecessor-version":[{"id":4272,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4269\/revisions\/4272"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/1670"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4269"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4269"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}