{"id":4326,"date":"2022-10-21T15:25:00","date_gmt":"2022-10-21T12:25:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4326"},"modified":"2026-02-27T13:59:54","modified_gmt":"2026-02-27T11:59:54","slug":"iomod-fpi-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/","title":{"rendered":"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1"},"content":{"rendered":"\n<p><strong>IOMod FPI <\/strong>is a fault passage indicator module for medium voltage applications that can be used as a standalone device or part of Elseta <a href=\"https:\/\/elseta.com\/mini-rtu\/\" data-type=\"project\" data-id=\"1126\">mini RTU<\/a> with voltages and currents based on sensors technology or with <a href=\"https:\/\/elseta.com\/measurement-adapters\/\" data-type=\"project\" data-id=\"2428\">adapters<\/a> connected to current and voltage transformers with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. <\/p>\n\n\n\n<p>Designed for short-circuit and earth fault indication with direction detection. IOMod FPI can be used for numerous applications like electrical distribution substations, photovoltaic and hydropower plants, and railway power supplies where the user needs them.<\/p>\n\n\n\n<p>IOMod FPI also calculates neutral current and voltage RMS values I0 and U0 as well as many other measurements like active, reactive, apparent power for every phase, power factors per phase, phase angles for currents and voltages, and more.<\/p>\n\n\n\n<p>Unique by the device size and functionality complexity, it perfectly fits into any application like a recloser, RTU cabinet, or switchgear retrofit project. This device enables utilities and distribution network operators (DNO) to digitalize substations into smart grid elements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Directional fault detection for all network types;<\/li>\n\n\n\n<li>Earth fault detection;<\/li>\n\n\n\n<li>50 Instantaneous overcurrent detection;<\/li>\n\n\n\n<li>50N Neutral instantaneous overcurrent detection;<\/li>\n\n\n\n<li>51\/67 Phase directional overcurrent detection;<\/li>\n\n\n\n<li>67N Neutral directional overcurrent detection;<\/li>\n\n\n\n<li>27 Under voltage detection (with VT or voltage sensors);<\/li>\n\n\n\n<li>59 Over voltage detection (with VT or voltage sensors);<\/li>\n\n\n\n<li>59N Neutral over voltage detection \/ permanent earth fault (with VT or voltage sensors);<\/li>\n\n\n\n<li>81HBL2 Inrush blocking for selected protections; <\/li>\n\n\n\n<li><strong>2 settings groups;<\/strong><\/li>\n\n\n\n<li>integration into Elseta mini RTU;<\/li>\n\n\n\n<li>Measurements of RMS values for currents, phase, and phase-to-phase voltages.<\/li>\n\n\n\n<li>Additional measurements of:\n<ul class=\"wp-block-list\">\n<li>Frequency;<\/li>\n\n\n\n<li>Active, reactive, and apparent power;<\/li>\n\n\n\n<li>Neutral voltage, neutral current;<\/li>\n\n\n\n<li>Power factor;<\/li>\n\n\n\n<li>Phase angle;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analog inputs measurement in 16-bit resolution.<\/li>\n\n\n\n<li>3x low-power (LoPo) current measuring inputs (225 mV) or 3x1A\/5A CT with the adapter.<\/li>\n\n\n\n<li>3x low-power (LoPo) voltage measuring inputs (3.25 V\/\u221a3) or 3x100V\/400V VT with the adapter.<\/li>\n\n\n\n<li>Frequency acquisition (Nominal frequencies: 50 and 60 Hz; Frequency range: 45\u201365 Hz).<\/li>\n\n\n\n<li>Communication port: RS485.<\/li>\n\n\n\n<li>Communication over Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-FPI V1.1<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 Current sensor inputs and 3 Voltage sensor inputs module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility*<\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Measurement values and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Analog inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">6x 16-bit resolution<\/td><\/tr><tr><td>Input types<\/td><td class=\"has-text-align-left\" data-align=\"left\">Channel-independent<\/td><\/tr><tr><td>Current inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><\/tr><tr><td>Current inputs measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">225 mV (IEC 61869-10) with <a href=\"https:\/\/elseta.com\/measurement-adapters\/\" data-type=\"project\" data-id=\"2428\">external adapter 1A \/ 5A<\/a><\/td><\/tr><tr><td>Current input impedance<\/td><td class=\"has-text-align-left\" data-align=\"left\">1 M\u03a9; &lt; 170 pF<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">1%<\/td><\/tr><tr><td>Voltage inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><\/tr><tr><td>Voltage input measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.25 V\/\u221a3 AC (IEC 61869-11) with <a href=\"https:\/\/elseta.com\/measurement-adapters\/\" data-type=\"project\" data-id=\"2428\">external adapter 100VAC \/ 400VAC<\/a><\/td><\/tr><tr><td>Voltage input impedance<\/td><td class=\"has-text-align-left\" data-align=\"left\">1 M\u03a9; &lt; 170 pF<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">1%<\/td><\/tr><tr><td>Frequency measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">45..65 Hz<\/td><\/tr><tr><td>Overvoltage protection<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00b120V<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-33VDC (full range)<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">40mA @ 12VDC, 20mA @ 24 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non-condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 17.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">* IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\" data-type=\"link\" data-id=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-fpi-iomod-fpi-13363\">IOMOD-FPI<\/a> &#8211;  3xCurrent 3xVoltage sensors module with IEC-101, IEC103, Modbus-RTU protocol support.<\/p>\n\n\n\n<p>IOMOD-FPI-RJ &#8211; 3xCurrent 3xVoltage sensors module with 2xRJ45 connectors and IEC-101, IEC103, Modbus-RTU protocol support.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD FPI inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>IOMod FPI is a fault passage indicator module for medium voltage applications that can be used as a standalone device or part of Elseta mini RTU with voltages and currents based on sensors technology or with adapters connected to current and voltage transformers with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":2493,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4326","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"IOMod FPI is a fault passage indicator module for medium voltage applications that can be used as a standalone device or part of Elseta mini RTU with voltages and currents based on sensors technology or with adapters connected to current and voltage transformers with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-27T11:59:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/\",\"url\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/\",\"name\":\"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png\",\"datePublished\":\"2022-10-21T12:25:00+00:00\",\"dateModified\":\"2026-02-27T11:59:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png\",\"width\":851,\"height\":566,\"caption\":\"IOMOD FPI\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | elseta.com","robots":{"index":"noindex","follow":"follow"},"og_locale":"lt_LT","og_type":"article","og_title":"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | Elseta","og_description":"IOMod FPI is a fault passage indicator module for medium voltage applications that can be used as a standalone device or part of Elseta mini RTU with voltages and currents based on sensors technology or with adapters connected to current and voltage transformers with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 [&hellip;]","og_url":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-02-27T11:59:54+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/","url":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/","name":"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png","datePublished":"2022-10-21T12:25:00+00:00","dateModified":"2026-02-27T11:59:54+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-FPI-1.png","width":851,"height":566,"caption":"IOMOD FPI"},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/project\/iomod-fpi-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"IOMod FPI \u2013 Fault Passage Indicator for MV Networks V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4326"}],"version-history":[{"count":2,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4326\/revisions"}],"predecessor-version":[{"id":4330,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4326\/revisions\/4330"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/2493"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4326"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4326"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4326"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}