{"id":4336,"date":"2022-10-21T15:38:00","date_gmt":"2022-10-21T12:38:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4336"},"modified":"2026-02-27T14:08:27","modified_gmt":"2026-02-27T12:08:27","slug":"iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/","title":{"rendered":"IOMod 4Cs4Vs &#8211; 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"overview\">Overview<\/h2>\n\n\n\n<p><strong>IOMod 4Cs4Vs <\/strong>is a stand-alone analog inputs measurement module for voltages and currents based on sensor technology with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. Designed to measure voltage and current values with high accuracy in real time. IOMod 4Cs4Vs can be used for numerous applications like electrical distribution substations, gas distribution substations, photovoltaic and hydropower plants, and railway power supplies where the user needs them. IOMod 4Cs4Vs calculates neutral current and voltage RMS values I0 and U0 as well as many other measurements like active, reactive, apparent power for every phase, power factors per phase, phase angles for currents and voltages, and harmonics.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analog inputs measurement in 16-bit resolution<\/li>\n\n\n\n<li>4x low-power (LoPo) current measuring inputs (225 mV)<\/li>\n\n\n\n<li>4x low-power (LoPo) voltage measuring inputs (3.25 V\/\u221a3)<\/li>\n\n\n\n<li>Frequency acquisition (nominal frequency 45 to 65 Hz)<\/li>\n\n\n\n<li>Calculation of RMS values for currents, phase, and phase-to-phase voltages<\/li>\n\n\n\n<li>Calculation of:\n<ul class=\"wp-block-list\">\n<li>Frequency;<\/li>\n\n\n\n<li>Active, reactive, and apparent power;<\/li>\n\n\n\n<li>Neutral voltage, neutral current;<\/li>\n\n\n\n<li>Power factor;<\/li>\n\n\n\n<li>Phase angle;<\/li>\n\n\n\n<li>Harmonics calculation;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Communication port: RS485<\/li>\n\n\n\n<li>Communication over Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-4CS4VS V1.1<\/td><\/tr><tr><td>Product description<\/td><td class=\"has-text-align-left\" data-align=\"left\">4 Current sensor inputs and 4 Voltage sensor inputs module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility, Serial console (putty)* <\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Measurement values and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Analog inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">8x 16-bit resolution<\/td><\/tr><tr><td>Input types<\/td><td class=\"has-text-align-left\" data-align=\"left\">Channel-independent<\/td><\/tr><tr><td>Current inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><\/tr><tr><td>Current inputs measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">225 mV (IEC 61869-10)<\/td><\/tr><tr><td>Current input impedance<\/td><td class=\"has-text-align-left\" data-align=\"left\">1 M\u03a9; &lt; 170 pF<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">1%<\/td><\/tr><tr><td>Voltage inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><\/tr><tr><td>Voltage inputs measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.25 V\/\u221a3 AC (IEC 61869-11)<\/td><\/tr><tr><td>Voltage input impedance<\/td><td class=\"has-text-align-left\" data-align=\"left\">1 M\u03a9; &lt; 170 pF<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">1%<\/td><\/tr><tr><td>Frequency measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">45..65 Hz<\/td><\/tr><tr><td>Overvoltage protection<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00b120V<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-33VDC (full range)<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">40mA @ 12VDC, 20mA @ 24 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % relative Feuchte bei 40\u00b0 C<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 17.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*  IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x, for devices with fw v1.x configuration can be done via USB port as Serial console interface like Putty.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\" rel=\"noreferrer noopener\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-4cs4vs-iomod-4cs4vs-12186\" data-type=\"link\" data-id=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-4cs4vs-iomod-4cs4vs-12186\">IOMOD-4CS4VS<\/a> &#8211;  4xCurrent 4xVoltage sensors module with IEC-101, IEC103, Modbus protocol support.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD 4CS4VS inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Overview IOMod 4Cs4Vs is a stand-alone analog inputs measurement module for voltages and currents based on sensor technology with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. Designed to measure voltage and current values with high accuracy in real time. IOMod 4Cs4Vs can be used for numerous applications like electrical distribution [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":1672,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4336","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"Overview IOMod 4Cs4Vs is a stand-alone analog inputs measurement module for voltages and currents based on sensor technology with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. Designed to measure voltage and current values with high accuracy in real time. IOMod 4Cs4Vs can be used for numerous applications like electrical distribution [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-27T12:08:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/\",\"url\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/\",\"name\":\"IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png\",\"datePublished\":\"2022-10-21T12:38:00+00:00\",\"dateModified\":\"2026-02-27T12:08:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png\",\"width\":851,\"height\":566},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IOMod 4Cs4Vs &#8211; 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | elseta.com","robots":{"index":"noindex","follow":"follow"},"og_locale":"lt_LT","og_type":"article","og_title":"IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | Elseta","og_description":"Overview IOMod 4Cs4Vs is a stand-alone analog inputs measurement module for voltages and currents based on sensor technology with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. Designed to measure voltage and current values with high accuracy in real time. IOMod 4Cs4Vs can be used for numerous applications like electrical distribution [&hellip;]","og_url":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-02-27T12:08:27+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/","url":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/","name":"IOMod 4Cs4Vs - 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png","datePublished":"2022-10-21T12:38:00+00:00","dateModified":"2026-02-27T12:08:27+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4CS4VSr.png","width":851,"height":566},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/project\/iomod-4cs4vs-4-current-and-4-voltage-sensor-input-analog-measurement-module-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"IOMod 4Cs4Vs &#8211; 4 Current and 4 Voltage Sensor Input Analog Measurement Module V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4336"}],"version-history":[{"count":1,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4336\/revisions"}],"predecessor-version":[{"id":4339,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4336\/revisions\/4339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/1672"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4336"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4336"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}