{"id":4342,"date":"2022-10-22T14:06:00","date_gmt":"2022-10-22T11:06:00","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=4342"},"modified":"2026-02-27T14:07:19","modified_gmt":"2026-02-27T12:07:19","slug":"iomod-4rtd-v1-1","status":"publish","type":"project","link":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/","title":{"rendered":"IOMod 4RTD V1.1"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"overview\">Overview<\/h2>\n\n\n\n<p><strong>IOMod 4RTD<\/strong> is a stand-alone Modbus RTU, IEC 60870-5-101, and IEC60870-5-103 temperature sensor device. Designed to measure indoor thermal statistics over a wide temperature range with high accuracy and repeatability even after frequent heating and cooling cycles. Equipped with 4 temperature measuring channels to enable temperature reading with default configuration.<\/p>\n\n\n\n<p><strong>IOMod 4RTD<\/strong> is an ideal solution for such applications as data acquisition, observation, process monitoring, testing, and remote measurement where high precision over a wide temperature range is needed. Further possible applications include plastics processing, microelectronics, textile processing, as well as numerous other.<\/p>\n\n\n\n<p>I<strong>OMod 4RTD<\/strong> is Modbus RTU, IEC 60870-5-101, or IEC60870-5-103 protocol compatible and can be connected in parallel with other equipment in a multi-drop installation scheme as in any SCADA system.<\/p>\n\n\n\n<p>When using <strong>IOMod 4RTD<\/strong> with <a href=\"\/wcc-lite\" data-type=\"URL\" data-id=\"\/wcc-lite\">WCC Lite gateway<\/a>, it is possible to monitor temperature (using 4 different sensors) over Ethernet LAN\u2019s or 3G\/4G(LTE)\/GSM\/GPRS networks. It is a powerful solution for remote monitoring and control, alarm management, and data logging of I\/O\u2019s on CloudIndustries.eu cloud platform.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temperature measurement of 0.5\u00b0C accuracy for all operating conditions<\/li>\n\n\n\n<li>Temperature sensing range: from -200 to 800 \u00b0C using platinum RTD sensors<\/li>\n\n\n\n<li>Modbus, IEC60870-5-103, IEC60870-5-101 communication over RS485 physical layer<\/li>\n\n\n\n<li>Selectable PT100 or PT1000 temperature RTD sensor and connection type (2, 3 or 4 wires) for each channel<\/li>\n\n\n\n<li>Configuration over USB console<\/li>\n\n\n\n<li>Drag and Drop firmware upgrade over USB mass storage<\/li>\n\n\n\n<li>LED indications for power, USB connection, sensor and temperature fault conditions for all channels<\/li>\n\n\n\n<li>Easy connection with WCC Lite gateway and CloudIndustries.eu platform<\/li>\n<\/ul>\n\n\n\n<p><strong>System<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analog inputs: 4 RTD (PT100 \/ PT1000)<\/li>\n\n\n\n<li>PC USB connection: Mini USB<\/li>\n\n\n\n<li>Input connectors: Screw terminal plug connector<\/li>\n<\/ul>\n\n\n\n<p><strong>Software<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Configuration: Over USB console<\/li>\n\n\n\n<li>Firmware upgrade: Over USB mass storage<\/li>\n<\/ul>\n\n\n\n<p><strong>Communication<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Communication standard: RS485<\/li>\n\n\n\n<li>Communication protocol: Modbus RTU, IEC 60870-5-101 and IEC 60870-5-103<\/li>\n\n\n\n<li>Speed: 600 \u2013 115200 baud<\/li>\n<\/ul>\n\n\n\n<p><strong>Electrical Characteristics<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Termination resistor: Software selectable, 120\u03a9<\/li>\n\n\n\n<li>Power supply: 9-33VDC (full range)<\/li>\n\n\n\n<li>Current consumption:&nbsp;40mA @ 12VDC, 20mA @ 24VDC<\/li>\n<\/ul>\n\n\n\n<p><strong>Mechanical Characteristics<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Operating temperature: -40 \u00f7 +85 \u00b0C<\/li>\n\n\n\n<li>Humidity:&nbsp;5-95% RH (non-condensing)<\/li>\n\n\n\n<li>Casing:&nbsp;IP20, blend PC\/ABS self-extinguishing, black<\/li>\n\n\n\n<li>Dimensions:&nbsp;119 (H) x 17.5 (W) x 101 (L), mm<\/li>\n\n\n\n<li>Mounting: DIN rail<\/li>\n\n\n\n<li>Warranty: 2 years<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD-4RTD V1.1<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">4 temperature sensor input module<\/td><\/tr><tr><td>Configuration software<\/td><td class=\"has-text-align-left\" data-align=\"left\">IOMOD Utility, Serial console (putty)* <\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Measurement values and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Analog inputs<\/td><td class=\"has-text-align-left\" data-align=\"left\">4 RTD (PT100 \/ PT1000)<\/td><\/tr><tr><td>Input supports sensors<\/td><td class=\"has-text-align-left\" data-align=\"left\">PT100 and PT1000 temperature RTD sensor<\/td><\/tr><tr><td>Input connection<\/td><td class=\"has-text-align-left\" data-align=\"left\">2, 3 or 4 wires connection<\/td><\/tr><tr><td>Temperature measurement range<\/td><td class=\"has-text-align-left\" data-align=\"left\">-200 to 800 \u00b0C using platinum RTD sensors<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.5\u00b0C accuracy for all operating conditions<\/td><\/tr><tr><td><strong>Interface and communication<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RS485 interface<\/td><td class=\"has-text-align-left\" data-align=\"left\">ANSI\/TIA\/EIA-485-A-1998<\/td><\/tr><tr><td>Communication protocols<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211; Modbus RTU Slave;<br>&#8211; IEC 60870-5-101 Slave;<br>&#8211; IEC 60870-5-103 Slave.<\/td><\/tr><tr><td>Baudrate<\/td><td class=\"has-text-align-left\" data-align=\"left\">600 \u2013 115200 <\/td><\/tr><tr><td>Parity<\/td><td class=\"has-text-align-left\" data-align=\"left\">None, Even, Odd<\/td><\/tr><tr><td>Terminating resistors<\/td><td class=\"has-text-align-left\" data-align=\"left\">120 Ohm (configurable)<\/td><\/tr><tr><td>USB interface<\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mini USB<\/td><\/tr><tr><td>Use<\/td><td class=\"has-text-align-left\" data-align=\"left\">Configuration\/Firmware upgrade<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-33VDC (full range)<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">40mA @ 12VDC, 20mA @ 24 VDC<\/td><\/tr><tr><td>Insulation voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">3 kV<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Relative humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">IP20<\/td><\/tr><tr><td><strong>Dimensions and installation instructions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 17.5 x 101 mm<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN Rail mounting<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*  IOMOD Utility is configuration tool for IOMOD devices with firmware v2.x, for devices with fw v1.x configuration can be done via USB port as Serial console interface like Putty.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/wiki.elseta.com\/shelves\/iomods-input-output-modules\" target=\"_blank\">Online documentation about IOMOD modules<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/documentation\" target=\"_blank\" rel=\"noreferrer noopener\">Brochures and Manuals to download<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/iomod-series-downloads\/page\/firmware-and-tools\" target=\"_blank\" rel=\"noreferrer noopener\">Firmware and tools<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wiki.elseta.com\/books\/other-downloads\">ISO downloads<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p><a href=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-4-rtd-iomod-4rtd-28\" data-type=\"link\" data-id=\"https:\/\/shop.elseta.com\/shop\/product\/iomod-4-rtd-iomod-4rtd-28\">IOMOD-4RTD<\/a> &#8211;  4xChannel PT100,PT1000 input module with IEC 60870-5-103, IEC 60870-5-101, or Modbus RTU Slave protocol<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">On request*:<\/h3>\n\n\n\n<p> * &#8211; IOMOD devices 8DI8DO, 8AI, 4RTD, 16DI, 8DI4RO, HT with firmware versions v1.x supports only 1 protocol. To change protocol is required to change firmware. All types of firmware are accessible to all customers without any additional payment. <\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD 4RTD inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Overview IOMod 4RTD is a stand-alone Modbus RTU, IEC 60870-5-101, and IEC60870-5-103 temperature sensor device. Designed to measure indoor thermal statistics over a wide temperature range with high accuracy and repeatability even after frequent heating and cooling cycles. Equipped with 4 temperature measuring channels to enable temperature reading with default configuration. IOMod 4RTD is an [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":1675,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[],"class_list":["post-4342","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IOMod 4RTD V1.1 | elseta.com<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IOMod 4RTD V1.1 | Elseta\" \/>\n<meta property=\"og:description\" content=\"Overview IOMod 4RTD is a stand-alone Modbus RTU, IEC 60870-5-101, and IEC60870-5-103 temperature sensor device. Designed to measure indoor thermal statistics over a wide temperature range with high accuracy and repeatability even after frequent heating and cooling cycles. Equipped with 4 temperature measuring channels to enable temperature reading with default configuration. IOMod 4RTD is an [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-27T12:07:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png\" \/>\n\t<meta property=\"og:image:width\" content=\"851\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/\",\"url\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/\",\"name\":\"IOMod 4RTD V1.1 | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png\",\"datePublished\":\"2022-10-22T11:06:00+00:00\",\"dateModified\":\"2026-02-27T12:07:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png\",\"width\":851,\"height\":566},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IOMod 4RTD V1.1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IOMod 4RTD V1.1 | elseta.com","robots":{"index":"noindex","follow":"follow"},"og_locale":"lt_LT","og_type":"article","og_title":"IOMod 4RTD V1.1 | Elseta","og_description":"Overview IOMod 4RTD is a stand-alone Modbus RTU, IEC 60870-5-101, and IEC60870-5-103 temperature sensor device. Designed to measure indoor thermal statistics over a wide temperature range with high accuracy and repeatability even after frequent heating and cooling cycles. Equipped with 4 temperature measuring channels to enable temperature reading with default configuration. IOMod 4RTD is an [&hellip;]","og_url":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-02-27T12:07:19+00:00","og_image":[{"width":851,"height":566,"url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/","url":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/","name":"IOMod 4RTD V1.1 | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png","datePublished":"2022-10-22T11:06:00+00:00","dateModified":"2026-02-27T12:07:19+00:00","breadcrumb":{"@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/IOMOD-4RTDr.png","width":851,"height":566},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/project\/iomod-4rtd-v1-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"IOMod 4RTD V1.1"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4342","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=4342"}],"version-history":[{"count":2,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4342\/revisions"}],"predecessor-version":[{"id":4346,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/4342\/revisions\/4346"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/1675"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=4342"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=4342"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=4342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}