{"id":5099,"date":"2026-06-01T14:39:22","date_gmt":"2026-06-01T11:39:22","guid":{"rendered":"https:\/\/elseta.com\/?post_type=project&#038;p=5099"},"modified":"2026-06-01T14:40:48","modified_gmt":"2026-06-01T11:40:48","slug":"products-sensors-ct-vt-adapters-rogowski-coils","status":"publish","type":"project","link":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/","title":{"rendered":"Rogowski Coil Current Transformers with Rogowski Coil Integrator"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"overview\">Overview<\/h2>\n\n\n\n<p>Elseta Rogowski Coils provide a flexible, safe, and accurate solution for measuring alternating current in power monitoring and automation applications. Designed for easy installation around existing conductors, Rogowski coils are ideal for projects where traditional current transformers are difficult to install or where the power line cannot be disconnected.<\/p>\n\n\n\n<p>Together with the Rogowski Coil Integrator (RCI), the coils can be used to collect current measurements and deliver them to compatible devices such as <a href=\"https:\/\/elseta.com\/products\/RTUs\/eRTU\/\">eRTU BCM1P<\/a>, <a href=\"https:\/\/elseta.com\/iomod-fpi\/\">IOMod FPI<\/a>, <a href=\"https:\/\/elseta.com\/iomod-meter\/\">IOMod Meter<\/a>, or <a href=\"https:\/\/elseta.com\/iomod-4cs4vs\/\">IOMod 4Cs4Vs<\/a> modules.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Flexible and lightweight current sensor for easy installation<\/li>\n\n\n\n<li>Suitable for installation around existing conductors without disconnecting the power line<\/li>\n\n\n\n<li>Designed for AC current measurement in power monitoring and automation systems<\/li>\n\n\n\n<li>Wide bandwidth range for monitoring power signals, harmonics, and transients<\/li>\n\n\n\n<li>Good linearity for accurate current measurement<\/li>\n\n\n\n<li>Output voltage proportional to the derivative of the input current<\/li>\n\n\n\n<li>Available in multiple coil sizes for different conductor diameters<\/li>\n\n\n\n<li>Default shielded twisted-pair signal cable for reliable signal transmission<\/li>\n\n\n\n<li>Coil IP67 waterproof grade<\/li>\n\n\n\n<li>Rogowski Coil Integrator for adapting coil measurements to compatible Elseta device inputs<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"features\">Typical applications<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power monitoring systems<\/li>\n\n\n\n<li>Fault passage indication<\/li>\n\n\n\n<li>Current measurement in automation systems<\/li>\n\n\n\n<li>Harmonic and transient monitoring<\/li>\n\n\n\n<li>Retrofitting projects where power lines cannot be interrupted<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"specs\">Specifications<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Device data<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Article number<\/td><td class=\"has-text-align-left\" data-align=\"left\">RCI<\/td><\/tr><tr><td>Product Description<\/td><td class=\"has-text-align-left\" data-align=\"left\">3x Rogowski Coils with Rogowski Coil Integrator<\/td><\/tr><tr><td>Warranty<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 years<\/td><\/tr><tr><td><strong>Measurements and functions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Measurement type<\/td><td class=\"has-text-align-left\" data-align=\"left\">Differential current sensor \/ Rogowski coil principle<\/td><\/tr><tr><td>Rated current<\/td><td class=\"has-text-align-left\" data-align=\"left\">500 A (other options available)<\/td><\/tr><tr><td>Output voltage<\/td><td class=\"has-text-align-left\" data-align=\"left\">RCI \u2013 225 mV RMS (IEC 61869-10)<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 1% at 25\u00b0C<\/td><\/tr><tr><td>Position error<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00b11%<\/td><\/tr><tr><td>Frequency range<\/td><td class=\"has-text-align-left\" data-align=\"left\">10 Hz \u2013 20 kHz<\/td><\/tr><tr><td>Phase shift<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264 1\u00b0<\/td><\/tr><tr><td>Coil signal cable length<\/td><td class=\"has-text-align-left\" data-align=\"left\">2 m default<\/td><\/tr><tr><td>Working voltage (coil)<\/td><td class=\"has-text-align-left\" data-align=\"left\">1000 VRMS CAT III \/ 600 VRMS CAT IV<\/td><\/tr><tr><td>Dielectric strength (coil)<\/td><td class=\"has-text-align-left\" data-align=\"left\">7400 VRMS \/ 1 min<\/td><\/tr><tr><td><strong>Power Supply<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Auxiliary power supply<\/td><td class=\"has-text-align-left\" data-align=\"left\">9-58VDC (full range)<\/td><\/tr><tr><td>Overvoltage protection<\/td><td class=\"has-text-align-left\" data-align=\"left\">35VDC (+\/-5%)<\/td><\/tr><tr><td>Reverse polarity protection<\/td><td class=\"has-text-align-left\" data-align=\"left\">Yes<\/td><\/tr><tr><td>Isolation<\/td><td class=\"has-text-align-left\" data-align=\"left\">Power supply circuit isolated<\/td><\/tr><tr><td>Power consumption<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 200mA @ 12 VDC<\/td><\/tr><tr><td><strong>Operating conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>Operating temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Storage temperature<\/td><td class=\"has-text-align-left\" data-align=\"left\">-40\u00b0C &#8230; 85\u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td class=\"has-text-align-left\" data-align=\"left\">max. 95 % (non-condensing)<\/td><\/tr><tr><td>Protection class<\/td><td class=\"has-text-align-left\" data-align=\"left\">Coil &#8211; IP67, RCI \u2013 IP20<\/td><\/tr><tr><td><strong>Dimensions and installation<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td>RCI case height x width x depth<\/td><td class=\"has-text-align-left\" data-align=\"left\">119 x 22.5 x 101 mm<\/td><\/tr><tr><td>Coil dimensions<\/td><td class=\"has-text-align-left\" data-align=\"left\">293 mm coil length, 80 mm window diameter<br>363 mm coil length, 105 mm window diameter<br>493 mm coil length, 150 mm window diameter<br>593 mm coil length, 180 mm window diameter<br>723 mm coil length, 240 mm window diameter<br>943 mm coil length, 300 mm window diameter<\/td><\/tr><tr><td>Installation type<\/td><td class=\"has-text-align-left\" data-align=\"left\">RCI &#8211; DIN Rail mounting<br>Coils &#8211; zip tied with a variable spacer for centering<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"docs\">Documentation<\/h2>\n\n\n\n<p>Coming soon<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"order\">Order<\/h2>\n\n\n\n<p>Coming soon<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact\">Contact Us<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"mailto: sales@elseta.com?subject=IOMOD FPI inquiry\" style=\"border-radius:5px\">Email<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:+37052032302\" style=\"border-radius:5px\">Call<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Overview Elseta Rogowski Coils provide a flexible, safe, and accurate solution for measuring alternating current in power monitoring and automation applications. Designed for easy installation around existing conductors, Rogowski coils are ideal for projects where traditional current transformers are difficult to install or where the power line cannot be disconnected. Together with the Rogowski Coil [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":5101,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[8],"project_tag":[118,105,45,44,41,43],"class_list":["post-5099","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-products","project_tag-fault-passage-indicator","project_tag-fpi","project_tag-iec101","project_tag-iec103","project_tag-iomod","project_tag-modbus"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Rogowski Coil Current Transformers for MV Substations | elseta.com<\/title>\n<meta name=\"description\" content=\"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rogowski Coil Current Transformers for MV Substations | Elseta\" \/>\n<meta property=\"og:description\" content=\"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/\" \/>\n<meta property=\"og:site_name\" content=\"Elseta\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/elseta.co\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-01T11:40:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png\" \/>\n\t<meta property=\"og:image:width\" content=\"2030\" \/>\n\t<meta property=\"og:image:height\" content=\"1549\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/\",\"url\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/\",\"name\":\"Rogowski Coil Current Transformers for MV Substations | Elseta\",\"isPartOf\":{\"@id\":\"https:\/\/elseta.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png\",\"datePublished\":\"2026-06-01T11:39:22+00:00\",\"dateModified\":\"2026-06-01T11:40:48+00:00\",\"description\":\"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks\",\"breadcrumb\":{\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png\",\"width\":2030,\"height\":1549},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/elseta.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/elseta.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Sensors & CT\/VT Adapters\",\"item\":\"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Rogowski Coil Current Transformers with Rogowski Coil Integrator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/elseta.com\/#website\",\"url\":\"https:\/\/elseta.com\/\",\"name\":\"elseta.com\",\"description\":\"Medium and Low voltage electricity automation and digitalisation solutions\",\"publisher\":{\"@id\":\"https:\/\/elseta.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/elseta.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/elseta.com\/#organization\",\"name\":\"Elseta\",\"url\":\"https:\/\/elseta.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"contentUrl\":\"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg\",\"width\":590,\"height\":800,\"caption\":\"Elseta\"},\"image\":{\"@id\":\"https:\/\/elseta.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/elseta.co\",\"https:\/\/www.linkedin.com\/company\/elseta\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Rogowski Coil Current Transformers for MV Substations | elseta.com","description":"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/","og_locale":"lt_LT","og_type":"article","og_title":"Rogowski Coil Current Transformers for MV Substations | Elseta","og_description":"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks","og_url":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/","og_site_name":"Elseta","article_publisher":"https:\/\/www.facebook.com\/elseta.co","article_modified_time":"2026-06-01T11:40:48+00:00","og_image":[{"width":2030,"height":1549,"url":"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/","url":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/","name":"Rogowski Coil Current Transformers for MV Substations | Elseta","isPartOf":{"@id":"https:\/\/elseta.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage"},"image":{"@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage"},"thumbnailUrl":"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png","datePublished":"2026-06-01T11:39:22+00:00","dateModified":"2026-06-01T11:40:48+00:00","description":"Flexible Rogowski coil current transformers for accurate AC current measurement, energy monitoring, and power quality applications in industrial systems in electrical networks","breadcrumb":{"@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#primaryimage","url":"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/Untitled-design-30.png","width":2030,"height":1549},{"@type":"BreadcrumbList","@id":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/rogowski-coils\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/elseta.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/elseta.com\/products\/"},{"@type":"ListItem","position":3,"name":"Sensors & CT\/VT Adapters","item":"https:\/\/elseta.com\/products\/sensors-ct-vt-adapters\/"},{"@type":"ListItem","position":4,"name":"Rogowski Coil Current Transformers with Rogowski Coil Integrator"}]},{"@type":"WebSite","@id":"https:\/\/elseta.com\/#website","url":"https:\/\/elseta.com\/","name":"elseta.com","description":"Medium and Low voltage electricity automation and digitalisation solutions","publisher":{"@id":"https:\/\/elseta.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elseta.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/elseta.com\/#organization","name":"Elseta","url":"https:\/\/elseta.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/","url":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","contentUrl":"https:\/\/elseta.com\/wp-content\/uploads\/ELSETA_logo.jpg","width":590,"height":800,"caption":"Elseta"},"image":{"@id":"https:\/\/elseta.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/elseta.co","https:\/\/www.linkedin.com\/company\/elseta\/"]}]}},"_links":{"self":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/5099","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/comments?post=5099"}],"version-history":[{"count":6,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/5099\/revisions"}],"predecessor-version":[{"id":5109,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project\/5099\/revisions\/5109"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media\/5101"}],"wp:attachment":[{"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/media?parent=5099"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_category?post=5099"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/elseta.com\/lt\/wp-json\/wp\/v2\/project_tag?post=5099"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}